Contrast ratio | 409:1 |
---|---|
Monitor model | belinea 10 19 20 |
Submitted | 24 Jan 2019 20:54 CET, by 89.64.*.* |
Camera model | Nikon D5300 |
Processing remarks | image file 1: Note: image seems to be noisy. Try reducing the ISO setting or increasing the exposure time. |
Black | |
Screen photo |
|
Luminance | 0.22 cd/m2 |
Luminance spread | 0.11 cd/m2 (2 standard deviations) |
Exposure value | –3.33 stops (aim for –2 to –3) |
Exposure spread | 0.71 stops |
Area used for calculation | 0.347 x 0.391 |
Camera settings | Exposure time: 3 ISO: 100 F-number: 2.8 Focal length: 25 mm (35 mm equivalent) Exposure compensation: -4 |
White | |
Screen photo |
|
Luminance | 91 cd/m2 |
Luminance spread | 28 cd/m2 (2 standard deviations) |
Exposure value | –3.21 stops (aim for –2 to –3) |
Exposure spread | 0.45 stops |
Area used for calculation | 0.347 x 0.391 |
Camera settings | Exposure time: 1/125 ISO: 100 F-number: 2.8 Focal length: 25 mm (35 mm equivalent) Exposure compensation: -4 |
The luminance values in cd/m2 are not very reliable, since camera sensitivities can easily differ up to 50% from their nominal value. Typically, the real luminance is 30% lower than this number. The area used for calculation is chosen such that it corresponds to a viewing angle of ±14° horizontally and ±10.5° vertically, which is equivalent to viewing the screen from a distance of about 1.5 times the diagonal size.
Unfortunately, there is a lot of variation in how cameras use EXIF settings. If photos from your camera your produce unusable results, try coming back in a few days. I review submitted pictures regularly and try to fix problems.