Contrast ratio of Iiyama ProLite 82783QSU

Contrast ratio 817:1
Monitor model Iiyama ProLite 82783QSU
Submitted 04 Nov 2018 16:43 CET, by 80.123.*.*
Camera model Sony SLT-A65V
Processing remarks


Black
Screen photo
Luminance 0.47 cd/m2
Luminance spread 0.13 cd/m2 (2 standard deviations)
Exposure value –1.8 stops   (aim for –2 to –3)
Exposure spread 0.4 stops
Area used for calculation 0.209 x 0.234
Camera settings Exposure time: 1.6   ISO: 400   F-number: 3.5
Focal length: 15 mm   (35 mm equivalent)
Exposure compensation: 0
White
Screen photo
Luminance 384 cd/m2
Luminance spread 19 cd/m2 (2 standard deviations)
Exposure value –1.45 stops   (aim for –2 to –3)
Exposure spread 0.07 stops
Area used for calculation 0.209 x 0.234
Camera settings Exposure time: 1/400   ISO: 400   F-number: 3.5
Focal length: 15 mm   (35 mm equivalent)
Exposure compensation: 0

The luminance values in cd/m2 are not very reliable, since camera sensitivities can easily differ up to 50% from their nominal value. Typically, the real luminance is 30% lower than this number. The area used for calculation is chosen such that it corresponds to a viewing angle of ±14° horizontally and ±10.5° vertically, which is equivalent to viewing the screen from a distance of about 1.5 times the diagonal size.

Unfortunately, there is a lot of variation in how cameras use EXIF settings. If photos from your camera your produce unusable results, try coming back in a few days. I review submitted pictures regularly and try to fix problems.